Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Radiol ; 57(1): 25-32, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25972368

RESUMO

BACKGROUND: Dual-source computed tomography (CT) enables CT coronary angiography (CTCA) with a prospectively electrocardiography (ECG)-triggered high-pitch spiral (HPS) mode. PURPOSE: To evaluate the radiation dose, image quality, and diagnostic acceptability of the HPS mode in CTCA and to compare HPS with the step-and-shoot (SAS) and low-pitch spiral (LPS) modes. MATERIAL AND METHODS: One hundred and thirty-eight patients who underwent CTCA with a 128-slice dual-source CT scanner were retrospectively included in this study. Seventeen patients (average heart rate of ≤65 beats per minute [bpm] prior to acquisition) were evaluated in the HPS mode, 88 (average heart rate of >65 and ≤80 bpm prior to acquisition) in the SAS mode, and 33 (average heart rate of >80 bpm prior to acquisition or patients with an unstable heart rhythm) in the LPS mode. Radiation dose and image noise were recorded for each patient. Diagnostic acceptability was graded using a four-point scale (1, unacceptable; 2, suboptimal; 3, acceptable; 4, fully acceptable). RESULTS: The effective dose in the HPS mode was 1.5 ± 0.2 mSv, which was lower than that in SAS (8.9 ± 2.7 mSv) and LPS (21.5 ± 4.3 mSv) modes. There were no significant differences in the image noise levels in the descending aorta and left atrium. The average per-patient diagnostic acceptability was 3.2, 3.6, and 3.7 in HPS, SAS, and LPS modes, respectively. CONCLUSION: The radiation dose is lower with HPS than with other modes, and the HPS mode-acquired images of patients with heart rates of ≤65 bpm are nearly acceptable for diagnostic image interpretation.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(12): 1201-8, 2015 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-26685831

RESUMO

We investigated dose reduction ability of an iterative reconstruction technology for low-dose computed tomography (CT) for lung cancer screening. The Sinogram Affirmed Iterative Reconstruction (SAFIRE) provided in a multi slice CT system, Somatom Definition Flash (Siemens Healthcare) was used. An anthropomorphic chest phantom (N-1, Kyoto Kagaku) was scanned at volume CT dose index (CTDIvol) of 0.50-11.86 mGy with 120 kV. For noise (standard deviation) and contrast-to-noise ratio (CNR) measurements, CTP486 and CTP515 modules in the Catphan (The Phantom Laboratory) were scanned. Radiological technologists were participated in the perceptual comparison. SAFIRE reduced the SD values by approximately 50% compared with filter back projection (FBP). The estimated dose reduction rates by SAFIRE determined from the perceptual comparison was approximately 23%, while 75% dose reduction rate was expected from the SD value reduction of 50%.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas
3.
Radiol Phys Technol ; 7(2): 254-61, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24515244

RESUMO

Our purpose in this study was to develop a functional form of radiography and to perform a quantitative analysis for the shoulder joint using a dynamic flat panel detector (FPD) system. We obtained dynamic images at a rate of 3.75 frames per second (fps) using an FPD system. Three patients and 5 healthy controls were studied with a clinically established frontal projection, with abduction of the arms. The arm angle, glenohumeral angle (G-angle), and scapulothoracic angle (S-angle) were measured on dynamic images. The ratio of the G-angle to the S-angle (GSR) was also evaluated quantitatively. In normal subjects, the G-angle and S-angle changed gradually along with the arm angle. The G-angle was approximately twice as large as the S-angle, resulting in a GSR of 2 throughout the abduction of the shoulder. Changes in G-angle and S-angle tended to be irregular in patients with shoulder disorders. The GSR of the thoracic outlet syndrome, recurrent dislocation of the shoulder joint, and anterior serratus muscle paralysis were 3-7.5, 4-9.5, and 3.5-7.5, respectively. The GSR of the anterior serratus muscle paralysis improved to approximately 2 after orthopedic treatment. Our preliminary results indicated that functional radiography by FPD and computer-aided quantitative analysis is useful for diagnosis of some shoulder disorders, such as the thoracic outlet syndrome, recurrent dislocation of the shoulder joint, and anterior serratus muscle paralysis. The technique and procedures described comprise a simple, functional shoulder radiographic method for evaluation of the therapeutic effects of surgery and/or rehabilitation.


Assuntos
Radiografia/instrumentação , Articulação do Ombro/diagnóstico por imagem , Adolescente , Adulto , Feminino , Humanos , Masculino , Paralisia/diagnóstico por imagem , Doses de Radiação , Recidiva , Luxação do Ombro/diagnóstico por imagem , Lesões do Ombro , Articulação do Ombro/inervação , Nervos Torácicos/diagnóstico por imagem , Síndrome do Desfiladeiro Torácico/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...